The Victron Energy Quattro II 48/5000/70-50 Inverter/Charger can be connected to two independent AC sources, for example shore-side power and a generator, or two generators. The Quattro-II will automatically connect to the active source. The main output has no-break functionality. In the event of a grid failure, or shore or generator power being disconnected, the Quattro-II takes over the supply to the connected loads. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will continue to operate without disruption. The second output is live only when AC is available on one of the inputs of the Quattro-II. Loads that should not discharge the battery, such as air-conditioning or a water heater, can be connected to this output.
The Quattro-II will prevent overload of a limited AC source, such as a generator or shore power connection. First, battery charging will automatically be reduced when otherwise an overload would occur. The second level will boost the output of a generator or shore side supply with power taken from the battery.
Please Note: Picture used for illustrative purposes ONLY.
Powercontrol & Powerassist | Yes |
Transfer Switch | 50 A |
Maximum Ac Input Current | 50 A |
Inverter | |
Dc Input Voltage Range | 38-66 V |
Output Voltage | 230 VAC - 2% |
Frequency | 50 Hz - 0,1% (1) |
Cont. Output Power At 25C (3) | 5000 VA |
Cont. Output Power At 25C | 4000 W |
Cont. Output Power At 40C | 3700 W |
Cont. Output Power At 65C | 3000 W |
Maximum Apparent Feed-In Power | 5000 VA |
Peak Power | 9000 W |
Maximum Efficiency | 96% |
Zero Load Power | 18 W |
Zero Load Power In Aes Mode | 12 W |
Zero Load Power In Search Mode | 2 W |
Charger | |
Ac Input Input Voltage Range | 187-265 VAC |
Input Frequency | 45 - 65 Hz power factor: 1 |
Charge Voltage 'Absorption' | 28,8 / 57,6 V |
Charge Voltage 'Float' | 27,6 / 55,2 V |
Storage Mode | 26,4 / 52,8 V |
Max. Battery Charge Current (4) | 70 A |
Battery Temperature Sensor | Yes |
General | |
Auxiliary Output | Yes (32A) Default setting: switches off when in inverter mode |
Programmable Relay (5) | Yes |
Protection (2) | a - g |
Ve.Bus Communication Port | For parallel and three-phase operation, remote monitoring and system integration |
General Purpose Com. Port | Yes, 2x |
Remote On-Off | Yes |
Operating Temperature Rang | e -40 to +65C (fan assisted cooling) |
Humidity (Non-Condensing) | max 95% |
Enclosure | |
Material & Colour | Steel, blue RAL 5012 |
Protection Category | IP22 |
Battery-Connection | M8 bolts |
230 V Ac-Connection | Screw terminals 13 mm (6 AWG) |
Weight | 30 kg |
Dimensions (Hxwxd) | 560 x 328 x 148 mm |
Free Shipping | No |
---|